Power Transformer
A Power transformer is used in
transmission network of higher voltages for step up and step down application
backed by decades of experience and expertise in transformers.
We have developed a comprehensive
range of power and extra high voltage transformers. These products are
engineered to perfection and are developed using quality raw material and
advanced manufacturing facilities and techniques.
Technical specifications
- RATINGS - UPTO
50 MVA(50,000 KVA)
- VOLTAGE
CLASS - 33,66,100,110,132 KV OTHER AS REQUIRED)
- APPLICABLE
STANDARDS - IS2026,IEC 60076,ANSI IEEE
- COOLING
– ONAN, ONAF–OIL NATURAL AIR FORCED (OTHER AS REQUIRED)
- SERVICE
- OUTDOOR /INDOOR
- FREQUENCY - 50HZ
,60HZ
- VECTOR
GROUP -
DYN5 ,DYN11/YNVNO (OTHER AS REQUIRED)
- TAPING
RANGE - OFF CIRCUIT AND ON LOAD TAP CHANGERS AS PER CUSTOMER SPEC.
- IMPEDANCE
- IN LINE WITH APPLICABLE STANDARDS.
Packaging
The packaging of the order is done in bundles according to standard export packaging, or it can be conveniently customized according to particular needs of the buyers.
Distribution Transformer
Power Distribution System that steps down the voltage to a usable level
at our homes /offices is called distribution transformer.
The Distribution Transformers are manufactured using quality raw
material and tested on various parameters for efficient working life our energy
efficient and durable transformers are capable of with standing variable
voltage supply.
Technical specifications:
- Ratings - up to 5000 k v a
- Voltage class - 66.11.15.20.33kv
- Cooling - ONAN
–Oil Natural Air Natural
- Service -
Indoor / Outdoor
- Frequency - 50 Hz
,60 Hz
- Vector Group - Dyn5 /Dyn11 (Other as required)
- Winding Material - Copper
/Aluminum off circuit and on load tap
- Taping Range -
Changers as per customer spec
- Impedance - In
line with applicable standards
Amorphous Core Transformer
We focus on energy efficiency and have been developing Amorphous Core
Transformers that helps in achieving very low no load losses.
Technical Specifications
- Ratings
- Single Phase 16 KVA-150 KVA
Three Phase 25 KVA 1000 KVA
- Voltage Class
- 66,11,15,20,33k (Other As Required)
- Applicable Standards - ISO 1180, IS 2026, IEC 6007
- Cooling
- ONAN- Oil Natural Air Natural
- Service
- Indoor /Outdoor
- Frequency
- 50HZ , 60HZ
- Vector group
- Dyn5/Dyn11 (Other as Required )
- Winding material
- Copper / Aluminum
- Taping range
- Off circuit and on load Tap (- Changers as per customer spec.)
- Impedance
- In line with applicable
standards